Power supply: | |
Nominal voltage | DC 12-24V |
Operating limits | DC 10.8-28.8V |
Immunity from micro power cuts | Typ.5 ms |
Max. Startup current | Max. 0.25A |
Max. absorbed power | 1.8 W |
Protection against polarity inversions | Yes |
Input parameters: | |
Input No | None |
Output parameters: | |
Output No | 2(AQ1-AQ2) |
Output signal | DC 0…10V/ 0..20mA |
Internal value and signal relationship | AQ*1(0..1000)= V1(0...10V)=I1(0...20mA) AQ*2(0..1000)= V2(0...10V)=I2(0...20mA) *= Extension Adr. |
Resolution | 0.01V or 0.02mA |
Accuracy at 25 °C | 0.02V or 0.05mA |
Other parameters: | |
Mounting | On 35-mm DIN rail, 4 WM wide, or wall mounting |
Operation temp. | -20℃-55℃ |
Storage temp. | -40℃-70℃ |
Weight | Approx.300g |
Certificate | CE |
Power supply: | |
Nominal voltage | DC 12-24V |
Operating limits | DC 10.8-28.8V |
Immunity from micro power cuts | Typ.5 ms |
Max. Startup current | Max. 0.25A |
Max. absorbed power | 1.8 W |
Protection against polarity inversions | Yes |
Input parameters: | |
Input No | None |
Output parameters: | |
Output No | 2(AQ1-AQ2) |
Output signal | DC 0…10V/ 0..20mA |
Internal value and signal relationship | AQ*1(0..1000)= V1(0...10V)=I1(0...20mA) AQ*2(0..1000)= V2(0...10V)=I2(0...20mA) *= Extension Adr. |
Resolution | 0.01V or 0.02mA |
Accuracy at 25 °C | 0.02V or 0.05mA |
Other parameters: | |
Mounting | On 35-mm DIN rail, 4 WM wide, or wall mounting |
Operation temp. | -20℃-55℃ |
Storage temp. | -40℃-70℃ |
Weight | Approx.300g |
Certificate | CE |
Expansions for PR-18/PR-24 PLC series | ||||
Model | Supply Voltage | Inputs | Outputs | G .W(g) |
PR-E-16AC-R | AC110~240V | 8DI | 4 relays(10A)+ 4relays(3A) | 300g |
PR-E-16DC-DA-R | DC12V–24V | 8 digital/4 analog | 4 relays(10A)+ 4relays(3A) | 300g |
PR-E-16DC-DA-TN | DC12V–24V | 8 digital/4 analog | 8 transistors(PNP) | 300g |
PR-E-AI-I | DC12V–24V | 4 points current signal input(0/4-20mA) | none | 300g |
PR-E-PT100 | DC12V–24V | 3 routes, temp range : -50℃- 200℃ | resolution: 0.5° | 300g |
PR-E-AQ-VI | DC 24V | None | 2 routes analog outputs(0-10V signal/( 0…20mA)signal) | 300g |
PR-RS485 | DC12V–24V | Isolated 485 converter, used to bring out the the terminals of RS485 port in PR-18/PR-24 series CPU for connection with third party devices. | 300g |
Expansions for PR-18/PR-24 PLC series | ||||
Model | Supply Voltage | Inputs | Outputs | G .W(g) |
PR-E-16AC-R | AC110~240V | 8DI | 4 relays(10A)+ 4relays(3A) | 300g |
PR-E-16DC-DA-R | DC12V–24V | 8 digital/4 analog | 4 relays(10A)+ 4relays(3A) | 300g |
PR-E-16DC-DA-TN | DC12V–24V | 8 digital/4 analog | 8 transistors(PNP) | 300g |
PR-E-AI-I | DC12V–24V | 4 points current signal input(0/4-20mA) | none | 300g |
PR-E-PT100 | DC12V–24V | 3 routes, temp range : -50℃- 200℃ | resolution: 0.5° | 300g |
PR-E-AQ-VI | DC 24V | None | 2 routes analog outputs(0-10V signal/( 0…20mA)signal) | 300g |
PR-RS485 | DC12V–24V | Isolated 485 converter, used to bring out the the terminals of RS485 port in PR-18/PR-24 series CPU for connection with third party devices. | 300g |