Small in size, Big in features
8 input (Digital)
4 relay output
-Relay output 10A(Max)
LCD Screen
-I/O status,user configurable messages(up to 64) with dynamic data,FBD program monitor and controls.
-Record on an alarm page and display the exact alarm occurrence time.
-Parameters can be modified in the alarming message.
Keypad
-With the programmable keys,you can reduce the number of used pushbuttons.
-Modify parameters via keypad panel without downloading new program.
RS485 port
-Built-in RS485 port with galvanic isolation for connection of the PLC with Modbus networks.
-Can work both as a master and as a slave device.
Ethernet port
-The built-in Ethernet port allows you to upload/download programs to the PLC,configure it,take advantage of the built-in web server,connect to other devices and more.
-The PLC can work as TCP server and TCP client at the same time,and also it can work as UDP server or UDP client as well.
Expansion port(up tp 16 modules)
-A wide variety of expansion modules such as Digital I/O, Analog I/O and communication modules are avarilable to create the application you need.
Micro SD Card slot for data-logging
-Data-logging is the process of collecting,in real time, determined process parameters such as conditions,values as well as the time that said information is collected,or noted.
MQTT protocol support
-Pub/Sub messaging protocol typically used to connect hardware to the Cloud, No more need for inermediate Gateway devices.
Small in size, Big in features
8 input (Digital)
4 relay output
-Relay output 10A(Max)
LCD Screen
-I/O status,user configurable messages(up to 64) with dynamic data,FBD program monitor and controls.
-Record on an alarm page and display the exact alarm occurrence time.
-Parameters can be modified in the alarming message.
Keypad
-With the programmable keys,you can reduce the number of used pushbuttons.
-Modify parameters via keypad panel without downloading new program.
RS485 port
-Built-in RS485 port with galvanic isolation for connection of the PLC with Modbus networks.
-Can work both as a master and as a slave device.
Ethernet port
-The built-in Ethernet port allows you to upload/download programs to the PLC,configure it,take advantage of the built-in web server,connect to other devices and more.
-The PLC can work as TCP server and TCP client at the same time,and also it can work as UDP server or UDP client as well.
Expansion port(up tp 16 modules)
-A wide variety of expansion modules such as Digital I/O, Analog I/O and communication modules are avarilable to create the application you need.
Micro SD Card slot for data-logging
-Data-logging is the process of collecting,in real time, determined process parameters such as conditions,values as well as the time that said information is collected,or noted.
MQTT protocol support
-Pub/Sub messaging protocol typically used to connect hardware to the Cloud, No more need for inermediate Gateway devices.
Technical Index
Specific characteristics | |
Input | I1--IC: 8DI(AC) |
Output | Q1--Q4 ( RELAY 10A 250VAC /5A 30VDC) |
Supply | AC 110~240V |
Weight | Approx. 350g |
Dimensions | Without packing: 95mm*90mm*61mm With packing: 107mm*96mm*73mm |
Expansion | YES(16PCS in max) |
Program size function blocks (FBD) | 512 function blocks |
Memory size function blocks (FBD) | 32K
|
LCD display | 4 lines of 16 characters and configurable backlighting |
Programming method | Function blocks |
Program memory | Flash EEPROM |
Data Logging | 4G TF Cord |
Back-up time in the event of power failure
| Program and settings in the controller: 10 years Program and settings in the plug-in memory: 10 years Data memory: 10 years |
Cycle time | FBD: typ. 0.6ms ~ 8.0ms |
Response time | Input acquisition time: + 1 to 2 cycle times |
Clock data retention | 25°C typ. 20 days |
Clock Drift | typ. ± 2 s/day |
Timer block accuracy | time base :s(Second) Resolution : +10 ms time base :m(Minute) Resolution: +1 s time base :h(Hour) Resolution: +1 min |
Start up time on power up | Typ. 4s |
Program language | FBD & Ladder |
Nominal voltage | 110 ~ 240 V ac |
Operating limits | 85 ~ 265 V ac |
Supply frequency range | 47 ~ 63 Hz |
Max. absorbed power | 49 mA (85V ac) ; 37 mA (265V ac) |
Isolation voltage | 1780V ac |
Inputs | |
Input voltage | 110 ~ 240 V ac |
Input current | 0.08 mA ; 85 Vac 0.25mA ; 265 V ac; |
(Analog Input) | None |
Accuracy at 25 °C (Analog Input) | None |
Logic 1 voltage threshold | >79 VAC; >0.06mA |
Logic 0 voltage threshold | < 40 VAC |
Input Response Time | Delay time at 0 to 1: 120V AC :Typ. 50 ms 240V AC:Typ. 30 ms Delay time at 1 to 0: 120V AC :Typ. 90 ms 240V AC:Typ.100 ms |
Maximum counting frequency | Typ.:4 HZ |
Sensor type | Contact or 3-wire PNP |
Input type | Resistive |
Outputs | |
Rated voltage | AC 250 V / DC 30 V |
Rated current | AC 250 V: 10 A DC 30 V ; 5A |
Electrical durability Expectancy | 105 Operations at Rated Resistive Load |
Mechanical life | 107 Operations at No Load condition |
Response time | Operate Time : 15 mSec. Max. Release Time : 10 mSec. Max. |
Frequency (Hz) | resistive load : 2 Hz inductive load : 0.5 Hz |
Communication ports parameters: | |
COM0_TTL port | COM0 : optional RS232/RS485 (via accessories :RS232 CABLE/PRO-RS485) Band Rate:4800;9600;19200;38400;57600;115200 Communication Protocol:MODBUS RTU;MODBUS ASCII |
Ext RS485 | COM1: optional RS485 (Via PR-RS485 expansion module) Band Rate:4800;9600;19200 Communication Protocol:MODBUS RTU;MODBUS ASCII |
Built-in RS485
| COM2: Built-in RS485 Band Rate:4800;9600;19200;38400;57600;115200 Communication Protocol:MODBUS RTU;MODBUS ASCII |
Ethernet port: | Built-In(10M/100M), 1.Can be used as program or communication 2.Can be used as modbus master or slave Communication Protocol:MODBUS TCP RTU ;MODBUS RTU |
Monitoring webserver page | Yes |
Xlogic | 1 xlogic works as tcp server can connect with 8 tcp client xlogics or other tcp devices. |
Xlogic | 1 xlogic works as TCP clients can connect with 8 different tcp servers separately in maximum |
Technical Index
Specific characteristics | |
Input | I1--IC: 8DI(AC) |
Output | Q1--Q4 ( RELAY 10A 250VAC /5A 30VDC) |
Supply | AC 110~240V |
Weight | Approx. 350g |
Dimensions | Without packing: 95mm*90mm*61mm With packing: 107mm*96mm*73mm |
Expansion | YES(16PCS in max) |
Program size function blocks (FBD) | 512 function blocks |
Memory size function blocks (FBD) | 32K
|
LCD display | 4 lines of 16 characters and configurable backlighting |
Programming method | Function blocks |
Program memory | Flash EEPROM |
Data Logging | 4G TF Cord |
Back-up time in the event of power failure
| Program and settings in the controller: 10 years Program and settings in the plug-in memory: 10 years Data memory: 10 years |
Cycle time | FBD: typ. 0.6ms ~ 8.0ms |
Response time | Input acquisition time: + 1 to 2 cycle times |
Clock data retention | 25°C typ. 20 days |
Clock Drift | typ. ± 2 s/day |
Timer block accuracy | time base :s(Second) Resolution : +10 ms time base :m(Minute) Resolution: +1 s time base :h(Hour) Resolution: +1 min |
Start up time on power up | Typ. 4s |
Program language | FBD & Ladder |
Nominal voltage | 110 ~ 240 V ac |
Operating limits | 85 ~ 265 V ac |
Supply frequency range | 47 ~ 63 Hz |
Max. absorbed power | 49 mA (85V ac) ; 37 mA (265V ac) |
Isolation voltage | 1780V ac |
Inputs | |
Input voltage | 110 ~ 240 V ac |
Input current | 0.08 mA ; 85 Vac 0.25mA ; 265 V ac; |
(Analog Input) | None |
Accuracy at 25 °C (Analog Input) | None |
Logic 1 voltage threshold | >79 VAC; >0.06mA |
Logic 0 voltage threshold | < 40 VAC |
Input Response Time | Delay time at 0 to 1: 120V AC :Typ. 50 ms 240V AC:Typ. 30 ms Delay time at 1 to 0: 120V AC :Typ. 90 ms 240V AC:Typ.100 ms |
Maximum counting frequency | Typ.:4 HZ |
Sensor type | Contact or 3-wire PNP |
Input type | Resistive |
Outputs | |
Rated voltage | AC 250 V / DC 30 V |
Rated current | AC 250 V: 10 A DC 30 V ; 5A |
Electrical durability Expectancy | 105 Operations at Rated Resistive Load |
Mechanical life | 107 Operations at No Load condition |
Response time | Operate Time : 15 mSec. Max. Release Time : 10 mSec. Max. |
Frequency (Hz) | resistive load : 2 Hz inductive load : 0.5 Hz |
Communication ports parameters: | |
COM0_TTL port | COM0 : optional RS232/RS485 (via accessories :RS232 CABLE/PRO-RS485) Band Rate:4800;9600;19200;38400;57600;115200 Communication Protocol:MODBUS RTU;MODBUS ASCII |
Ext RS485 | COM1: optional RS485 (Via PR-RS485 expansion module) Band Rate:4800;9600;19200 Communication Protocol:MODBUS RTU;MODBUS ASCII |
Built-in RS485
| COM2: Built-in RS485 Band Rate:4800;9600;19200;38400;57600;115200 Communication Protocol:MODBUS RTU;MODBUS ASCII |
Ethernet port: | Built-In(10M/100M), 1.Can be used as program or communication 2.Can be used as modbus master or slave Communication Protocol:MODBUS TCP RTU ;MODBUS RTU |
Monitoring webserver page | Yes |
Xlogic | 1 xlogic works as tcp server can connect with 8 tcp client xlogics or other tcp devices. |
Xlogic | 1 xlogic works as TCP clients can connect with 8 different tcp servers separately in maximum |
Installation Dimensions
Installation Dimensions