Constant voltage mode power supplies International general full scope Small volume, light weight, high efficiency Protections: short circuit/overload/overvoltage

  • RPS-60-S24
  • RIEVTECH
Quantity:
Features:

Ø Universal AC input range(90~264Vac)
Ø 300Vac surge for 3 seconds
Ø High efficiency, long life and high reliability
Ø Output protections: OVP/OLP/SCP
Ø Wide operating ambient temp (-25~50)
Ø Can be installed on TS-35/7.5 or 35/15
Ø 100% full load burn-in test
Ø PCB with conformal coating
Ø Suitable for critical applications
Ø Cooling by free air convection
Ø 18 months warranty 
MODEL RPS-60-S12 RPS-60-S24 RPS-60-S48
OUTPUT DC Output 12V 24V 48V
Rated Current 5A 2.5A 1.25A
Current Range     Note 1 0~5A 0~2.5A 0~1.25A
Ripple and Noise  Note 2 10~50 ≤60mV ≤50mV ≤120mV
-25~10 ≤120mV ≤100mV ≤240mV
Voltage ADJ.  Range 12~14V 24~28V 48~56V
Voltage Accuracy ±1.0%
Line Regulation ±0.5%
Load Regulation ±1%
Set-up Time <1.5S  @230Vac  Full load
Hold up Time ≥20mS  @230Vac  Full load
Temperature Coefficient ±0.03%/
Overshoot and Undershoot <5.0%
INPUT Voltage Range    90Vac~264Vac, 127VDC-370VDC(input V+ connect L, input V- connect N)
Frequency Range 47Hz~63Hz
Efficiency (Typical) @230Vac 86% 88% 89%
AC Current (max.) <1.6A
Inrush Current (Typical) 65A/230Vac   Cold start 50A/230Vac   Cold start 65A/230Vac   Cold start
Leakage Current Input—output: ≤0.25mA   Input—PE: ≤3.5mA
PROTECTION Over Load 6~7.5A
Hiccup mode, auto recovery
3~4A
Hiccup mode, auto recovery
1.5~2.5A
Hiccup mode, auto recovery
Over voltage 15.4~18V
Hiccup mode, auto recovery
28.8~31.2V
Hiccup mode, auto recovery
58~63V
Hiccup mode, auto recovery
Short Circuit Long-term mode, auto recovery
ENVIRONMENT Operatingamb.Temp.&Hum. -25~50;  20%~90%RH  No condensing
Storage Temp. & Hum. -40~85;  5%~95%RH  No condensing
SAFETY&
EMC 
Note 3
Safety Standards UL60950, EN60950
Withstand Voltage Primary-Secondary: 3KVac/10mA;  
Primary-PE: 1.5KVac/10mA;
Secondary-PE: 0.5KVac/10mA
Isolation Resistance >10M ohms
EMC Emission Compliance to EN55022, EN55024 Class B
Harmonic Current Compliance to EN61000-3-2CLASS A
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level
OTHERS MTBF (MIL-HDBK-217F) 590,000Hrs (25, Full load)
Dimension  (L*W*H) 103.7*32*97.5mm
Cooling method Cooling by free air convection
 
NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and 25 of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on www.rievtech.com.

Contact Us

Unit 506-508 , Zone A3, No.99 Gao Hu Road, Jiang Ning Economy Development District, Jiangning District, Nanjing city, China,  
Zip code :211100
+86 25 52713690
+86 25 52713691

Fax: +86 25 52713693
info@rievtech.com
sales@rievtech.com
Copyright 2014 Rievtech Electronic Co.,Ltd All Rights Reserved. 
About Us
Site Map