Model | RPS-15-12 | RPS-15-24 |
Output | DC voltage | 12V | 24V |
Rated current | 1.25A | 0.63A |
Current range | 0 ~ 1.25A | 0 ~ 0.63A |
Rated power | 15W | 15W |
Ripple noise | 120mVp-p | 150mVp-p |
Voltage ADJ. range | 10.28--13.2V | 21.6--26.4V |
Voltage tolerance | ±1.0% | ±1.0% |
Line regulation | ±1.0% | ±1.0% |
Load regulation | ±1.0% | ±1.0% |
Setup, rise time | 1000ms, 50ms/230VAC 200ms, 30ms/115VAC at full load |
Hold time(Typ.) | 70ms/230VAC 16ms/115VAC at full load |
Input | Voltage range | 85 ~ 264VAC 120 ~ 370VDC |
Frequency range | 47 ~ 63Hz |
Efficiency(Typ.) | 84% | 85% |
AC current | 0.88A/115VAC 0.48A/230VAC |
Inrush current(max.) | COLD START 35A/115VAC 65A/230VAC |
Protection | Overload | 105--160% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
Over voltage | 13.8 ~ 16.2V | 27.6 ~ 32.4V |
Protection type: Shut down o/p voltage, re-power on to recover |
Environment | Working temp. | -20 ~ +60ºC |
Working humidity | 20 ~ 90% RH non-condensing |
Storage Temp. humidity | -40 ~ +85ºC, 10 ~ 95% RH |
Temp. coefficient | ±0.03%/ºC (0 ~ 50ºC) |
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
Safety&EMC | Safety standards | Design refer to TUV EN60950-1, EN50178 |
Withstand voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
EMI conduction&radiation | Compliance to EN55022 (CISPR22) Class B |
Others | Harmonic current | Compliance to EN61000-3-2,-3 |
EMS immunity | Compliance to EN61000-4-2, 3, 4, 5; ENV50204, EN55024, Light industry level, criteria A |
MTBF | 1172.3K hrs min. MIL-HDBK-217F (25ºC) |
Dimension | 25×93×56mm(W x H x D) |
Packing | 0.1Kg; 140pcs/15KG/0.92CUFT |