Model | RPS-100-12 | RPS-100-24 |
Output | DC voltage | 12V | 24V |
Rated current | 7.5A | 4.0A |
Current range | 0 ~ 7.5A | 0 ~ 4.0A |
Rated power | 90W | 96W |
Ripple noise | 120mVp-p | 150mVp-p |
Voltage ADJ. range | 10.8--13.2V | 21.6--26.4V |
Voltage tolerance | ±1.0% | ±1.0% |
Line regulation | ±1.0% | ±1.0% |
Load regulation | ±1.0% | ±1.0% |
Setup, rise time | 800ms, 80ms, /230VAC at full load |
Hold time(Typ.) | 60ms/230VAC |
Input | Voltage range | 85 ~ 264VAC or 120 ~ 370VDC |
Frequency range | 47 ~ 63Hz |
Efficiency(Typ.) | 86% | 87% |
AC current | 1.5A/115VAC 0.75A/230VAC |
Inrush current(max.) | COLD START28A/115VAC 56A/230VAC |
Protection | Overload | 105--150% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
Over voltage | 13.8 ~ 16.2V | 27.6 ~ 32.4V |
Protection type: Shut down o/p voltage, re-power on to recover |
Over temperature | T>135ºC typical value (U1) detection power transistor radiator |
Protection type: Shut down o/p voltage, re-power on to recover |
Environment | Working temp. | -20 ~ +60ºC |
Working humidity | 20 ~ 90% RH non-condensing |
Storage Temp. humidity | -40 ~ +85ºC, 10 ~ 95% RH |
Temp. coefficient | ±0.03%/ºC (0 ~ 50ºC) |
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
Safety&EMC | Safety standards | Design refer to TUV EN60950-1, EN50178 |
Withstand voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
EMI conduction&radiation | Compliance to EN55022 (CISPR22) Class B |
Others | Harmonic current | Compliance to EN61000-3-2,-3 |
EMS immunity | Compliance to EN61000-4-2, 3, 4, 5; ENV50204, EN55024, Light industry level, criteria A |
MTBF | 364.6Khrs Min. MIL-HDBK-217F (25ºC) |
Dimension | 100×93×56mm(W x H x D) |
Packing | 0.45Kg; 24pcs/156KG/1.2CUFT |